### General & Total Parameters

| Parameter | Unit | Register |
| ---- |
| Frequency | Hz | 06 |
| Total Current | A | 0A |
| Neutral Current | A | 0B |
| Total Power Factor | None | 0F |
| Total Active Power | W | 13 |
| Total Reactive Power | var | 17 |
| Total apparent Power | VA | 1B |
| System Phase Angle | Degrees | 1F |
| Maximum Total System Power Demand | W | 20 |
| Maximum Total System Reactive Power Demand | var | 21 |
| Maximum Total System Apparent Power Demand | VA | 22 |
| Maximum Neutral Current Demand | A | 26 |
| Import Active Energy | kWh | 2D |
| Export Active Energy | kWh | 2E |
| Total kWh | kWh | 2F |
| Import Reactive Energy | kvarh | 30 |
| Export Reactive Energy | kvarh | 31 |
| Total kVArh | kVArh | 32 |
| Total kVAh | kVAh | 33 |
| Active Energy by Algebraic Sum Method | kWh | 46 |
| Reactive Energy by Algebraic Sum Method | kVArh | 47 |
| Resettable Total Active Energy | kWh | 48 |
| Resettable Total Reactive Energy | kvarh | 49 |
| Resettable Import Active Energy | kWh | 4A |
| Resettable Export Active Energy | kWh | 4B |
| Resettable Import Reactive | kVArh | 4C |
| Resettable Export Reactive Energy | kVArh | 4D |


### Phase 1 (L1) Parameters

| Parameter | Unit | Register |
| ---- |
| L1-N Voltage | V | 00 |
| L1-2 Voltage | V | 03 |
| L1 Current | A | 07 |
| L1 Power Dactor |  | 0C |
| L1 Active Power | W | 10 |
| L1 Reactive Power | var | 14 |
| L1 Apparent Power | VA | 18 |
| L1 Phase Angle | Degrees | 1C |
| Maximum L1 Current Demand | A | 23 |
| Phase 1 L/N Volts THD | % | 27 |
| Phase 1 Current THD | % | 2A |
| L1 Import kWh | kWh | 34 |
| L1 Export kWh | kWh | 37 |
| L1 Total kWh | kWh | 3A |
| L1 Import kVArh | kVArh | 3D |
| L1 Export kVArh | kVArh | 40 |
| L1 Total kVArh | kVArh | 43 |


### Phase 2 (L2) Parameters

| Parameter | Unit | Register |
| ---- |
| L2-N Voltage | V | 01 |
| L2-3 Voltage | V | 04 |
| L2 Current | A | 08 |
| L2 Power Factor |  | 0D |
| L2 Active Power | W | 11 |
| L2 Reactive Power | var | 15 |
| L2 Apparent Power | VA | 19 |
| L2 Phase Angle | Degrees | 1D |
| Maximum L2 Current Demand | A | 24 |
| Phase 2 L/N Volts THD | % | 28 |
| Phase 2 Current THD | % | 2B |
| L2 Import kWh | kWh | 35 |
| L2 Export kWh | kWh | 38 |
| L2 Total kWh | kWh | 3B |
| L2 Import kVArh | kVArh | 3E |
| L2 Export kVArh | kVArh | 41 |
| L2 Total kVArh | kVArh | 44 |


### Phase 3 (L3) Parameters

| Parameter | Unit | Register |
| ---- |
| L3-N Voltage | V | 02 |
| L3-1 Voltage | V | 05 |
| L3 Current | A | 09 |
| L3 Power Factor |  | 0E |
| L3 Active Power | W | 12 |
| L3 Reactive Power | var | 16 |
| L3 Apparent Power | VA | 1A |
| L3 Phase Angle | Degrees | 1E |
| Maximum L3 Current Demand | A | 25 |
| Phase 3 L/N Volts THD | % | 29 |
| Phase 3 Current THD | % | 2C |
| L3 Import kWh | kWh | 36 |
| L3 Export kWh | kWh | 39 |
| L3 Total kwh | kWh | 3C |
| L3 Import kVArh | kVArh | 3F |
| L3 Export kVArh | kVArh | 42 |
| L3 Total kVArh | kVArh | 45 |