Articles on: Eastron

How do I reset the SDM530 to its default configuration?


What is the default configuration for the SDM530?


By default, the SDM530 is configured with the following settings.


Setting

Default Value

Upload Interval

30 mins

Parameters per Uplink

5

Offline Detection

255 mins


The default parameters, sent every upload interval (30 minutes by default), are as follows.


Register

Parameter

Unit

28

Total kWh

kWh

2E

DI-1 Count

2F

DI-2 Count

2D

Relay State

0F

Total Power Factor

How to set the default configuration for the SDM530


Unlocking the device


To send downlinks that reconfigure your SDM530 to the default settings, the device must first be unlocked. This is done by reading the password and then writing it back to the device. To perform these steps, you can send the following downlinks.


Make sure to wait for a response uplink after sending each downlink


01 03 00 18 00 02 44 0C

01 10 00 18 00 02 04 44 7A 00 00 C6 2C


If you are unsure whether the meter configuration has been unlocked, you can send the following command.


01 03 00 0E 00 02 A5 C8


Receiving the following uplink indicates that the device is unlocked.


01 03 04 3F 80 00 00 F7 CF


The following uplink indicates the device is still locked.


01 03 04 00 00 00 00 FA 33


Setting the default configuration for the device


Once the device is unlocked, the following downlinks can be sent to reset the device to its default configuration.


Make sure to wait for a response uplink after sending each downlink


0110FE1200010200057AEE

0110FE02000F1E282E2F2D0FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF3B33

0110FE01000102001E3846

0110FE1300010200FFFB7C